Marie Poirier-Quinot

, par  Marie Poirier-Quinot

Maître de Conférence Universitaire

Contact : Marie Poirier-Quinot

Fonction : enseignant-chercheur, HDR

Localisation : Bureau : 302 - Bâtiment : 220
Campus : Orsay - Vallée

Adresse : IR4M, Bât 220, Université Paris Sud
15, rue Georges Clemenceau
91405 Orsay Cedex

Tél. : 01 69 15 40 03
Fax. : 01 69 15 41 36

http://cluster.uvsq.fr/marie-poirier-quinot/ufr-des-sciences/2000


Marie Poirier-Quinot received her Ph.D. in physics from the Université Paris Sud, Orsay (France) in 2004. In 2005 she obtained a permanent teaching position at the Université Paris Sud associated to U2R2M research unit. His research activities are in the field of instrumental and methodological development for Magnetic Resonance micro Imaging. One part of her work was more specifically focused on the development of highly sensitivity NMR detection systems incorporating cutting edge technologies such as high temperature superconductors or microtechnological fabrication processes. The other main part of her activity is the tissue characterization, particularly the detection of labeled cells in different media (in vivo, biodegradable scaffolds etc…). She is now in charge of the research activities conducted at IR4M on the implementation and improvement of highly sensitive RF detection systems and their applications in micro imaging.
In addition to her research activities, Dr. Marie Poirier-Quinot is Vice President of the Physics Department of UFR d’Orsay.

Associations

GERM - http://www.germ.asso.fr

membre du bureau

SFRMBM - http://www.sfrmbm.fr/index.html

membre du bureau


Main research activities

Les limites de la Sensibilité en IRM

Instrumentation :

  • Development of RF instrumentation High Critical Temperature Superconducting (HCTS) coil and dedicated electronics (simulation, development, characterization, integration in the acquisition channel) at differnts magnetic fields : 1.5 (clinical), 4.7 (small animal) and 7T (small animal)
  • Fundamental studies of the HCTS material performance evaluation via different technic (Magneto optique, electronics measurement...)
  • Cryogenic system development for HCTS coil characterization

Agent de Contraste IRM :

  • Sensibilité de detection d’agent de contraste
  • Paramagnétique
  • Superparamagnétique

Applications :

  • MRµI Magnetic Resonance Micro Imaging
  • MRµE Magnetic Resonance Micro Elastography
  • Detection of labeled cells
  • Tissue engineering
  • Histologie IRM

Main teaching activities

Imagerie Médicale

  • les bases de l’IRM
    initiation à l’IRM


  • Echographie
  • Instrumentation
    kit antennes RF pour l’IRM


  • Produit de contraste en IRM
    produits de contraste en IRM


Outils pour la physique – Mesure et détection

  • du capteur à la numérisation du signal
outils pour la physique - mesure et détection - introduction


Électronique analogique – étude des différents éléments d’une chaîne d’acquisition classiquement utilisée en physique expérimentale

  • Notions signal analogique, loi de Kirchoff, Thevenin/Norton, notion de bruit…
  • Quadripôle Filtrage (passif, actif, synthèse, réalisation)
  • Amplification faible niveau (amplificateur opérationnel, transistor , facteur de bruit)
  • Echantillonage, échantillonneur bloqueur (capacité commuté)
  • Conversion numérique-analogique/analogique-numérique

    Technique numérique : filtrage numérique (synthèse de filtre RIF et RII)

Initiation Matlab

initiation à matlab

Électronique numérique (notion de base, algebre booléenne, séquentielle, combinatoire, machine de Moore)

Initiation à la physique - école primaire et à l’occasion des fêtes de la science


CV


Post doctorat à la Medical school of Harvard – Brigham and Women’s Hospital, Boston, MA. Réalisation d’une étude portant sur ”23Na et 1H MR Relaxography of the Perfused Rat Heart” sous la direction de James Balschi


Docteur en Sciences de l’Université Paris Sud en Electronique, mention imagerie médicale ; “ Microscopie locale par résonance magnétique chez l’homme et le petit animal à l’aide d’antennes miniatures en cuivre ou en céramique supraconductrice” - préparée à l’Unité de Recherche en Résonance Magnétique Médicale (U2R2M UMR 8081 – dir. Jacques Bittoun) sous la direction de Luc Darrasse

Diplôme d’Etude Approfondie en Physique, d’Imagerie Médicale aspects physiques, informatiques et physiologiques
"Détection du Phosphore dans la peau par Spectroscopie par Résonance Magnétique Nucléaire à Haute Résolution Volumique " sous la direction de B. Querleux



Maîtrise de Physique Appliquée 2000
Licence Physique Appliquée 1999
DEUG de Mathématiques Informatique 1998


Thèse de sciences :

Thèse de Science

Habilitation à Diriger les Recherches :

document HDR

Publications :

  1. Kriegl, R., Laistler, E., Hosseinnezadian S., Scmid A., Moser, E., Poirier-Quinot, M., Darrasse, L., Ginefri, J-C Multi-turn multi-gap transmission line resonators – Concept, design and first implementation at 4.7 T and 7 T. Journal of Magnetic Resonance. 2016, 273, pp : 65-72.
  2. Li Z., Hosseinnezadian S., Guillot G., Willoquet G., Jourdain L, Poirier-Quinot M., Darrasse L., Ginefri J-C. Study of two contact-less tuning principles for small monolithic radiofrequency MRI coils and development of an automated system based on piezoelectric motor. Sensors and Actuators A Physical. 2016, 241, pp : 176-189.
  3. Khairi R., Razek A., Bernard L., Corcolle R., Bernard Y., Pichon L., Poirier-Quinot M., Ginefri J-C. EMC analysis of MRI environment in view of optimized performance and cost of image-guided interventions. International Journal of Applied Electromagnetics and Mechanics. 2016, 51 (S1)n pp : s67-s74.
  4. Gargam N., Darrasse L., Raynaud J-B, Ginefri J-C, Robert P and Poirier-Quinot M, An experimental system to detect a labeled cell monolayer in a microfluidic environment, JMRI, 2015 In press
  5. Laistler, E., et al., In vivo MR imaging of the human skin at subnanoliter resolution using a superconducting surface coil at 1.5 tesla. J Magn Reson Imaging, 2013.
  6. Lambert, S., et al., High-temperature superconducting radiofrequency probe for MRI applications operated below ambient pressure in a simple liquid-nitrogen cryostat. Review of Scientific Instruments, submitted 2012 : p. in press
  7. Ginefri, J.C., et al., Implanted, inductively-coupled, radiofrequency coils fabricated on flexible polymeric material : application to in vivo rat brain MRI at 7 T. J Magn Reson, 2012. 224 : p. 61-70.
  8. Luciani, A., et al., Adipose tissue macrophages : MR tracking to monitor obesity-associated inflammation. Radiology, 2012. 263(3) : p. 786-93.
  9. Couty, M., M. Woytasik, J.-C. Ginefri, A. Rubin, E. Martincic, M. Poirier-Quinot, L. Darrasse, F. Boumezbeur, F. Lethimonnier, M. Tatoulian, and E. Dufour-Gergam, Fabrication and Packaging of Flexible Polymeric Microantennae for in Vivo Magnetic Resonance Imaging. Polymers, 2012. 4(1) : p. 656-673.
  10. Zhang, Y., et al., Active trans-plasma membrane water cycling in yeast is revealed by NMR. Biophys J, 2011. 101(11) : p. 2833-42.
  11. Zhang, Y., et al., Discrimination of intra- and extracellular 23Na+ signals in yeast cell suspensions using longitudinal magnetic resonance relaxography. J Magn Reson, 2010. 205(1) : p. 28-37.
  12. Poirier-Quinot, M., et al., High-Resolution 1.5-Tesla Magnetic Resonance Imaging for Tissue-Engineered Constructs : A Noninvasive Tool to Assess Three-Dimensional Scaffold Architecture and Cell Seeding. Tissue Engineering Part C-Methods, 2010. 16(2) : p. 185-200.
  13. Vats, N., et al., Magnetic tagging of cell-derived microparticles : new prospects for imaging and manipulation of these mediators of biological information. Nanomedicine (Lond), 2010. 5(5) : p. 727-38.
  14. Poirier-Quinot, M., et al., Performance of a miniature high-temperature superconducting (HTS) surface coil for in vivo microimaging of the mouse in a standard 1.5T clinical whole-body scanner. Magnetic Resonance in Medicine, 2008. 60(4) : p. 917-927.
  15. Smirnov, P., et al., In vivo single cell detection of tumor-infiltrating lymphocytes with a clinical 1.5 Tesla MRI system. Magnetic Resonance in Medicine, 2008. 60(6) : p. 1292-1297.
  16. Girard, O., et al., Method for nonlinear characterization of radio frequency coils made of high temperature superconducting material in view of magnetic resonance imaging applications. Rev Sci Instrum, 2007. 78(12) : p. 124703.
  17. Woytasik, M., et al., Characterization of flexible RF microcoils dedicated to local MRI Microsystem Technologies 2007. 13(11-12) : p. 1575-1580.
  18. Ginefri, J.C., et al., Technical aspects : development, manufacture and installation of a cryo-cooled HTS coil system for high-resolution in-vivo imaging of the mouse at 1.5 T. Methods, 2007. 43(1) : p. 54-67.
  19. Poirier-Quinot, M., et al., Preliminary ex vivo 3D microscopy of coronary arteries using a standard 1.5 T MRI scanner and a superconducting RF coil. MAGMA, 2005. 18(2) : p. 89-95.
  20. Ginefri, J.C., et al., Contrast-enhanced dynamic MRI protocol with improved spatial and time resolution for in vivo microimaging of the mouse with a 1.5-T body scanner and a superconducting surface coil. Magn Reson Imaging, 2005. 23(2) : p. 239-43.
  21. Woytasik M. , E.D.-G., J.-P. Grandchamp, E. Martincic, M. Poirier-Quinot, J.-C. Ginefri, L. Darrasse, J. Vautier, Copper Microcoils dedicated to NMR imaging MME, 2004.

Navigation

AgendaTous les événements